<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1726-4634</journal-id>
<journal-title><![CDATA[Revista Peruana de Medicina Experimental y Salud Pública]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Peru Med Exp Salud Publica]]></abbrev-journal-title>
<issn>1726-4634</issn>
<publisher>
<publisher-name><![CDATA[Instituto Nacional de Salud]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1726-46342012000200018</article-id>
<article-id pub-id-type="doi">10.1590/S1726-46342012000200018</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Acciones de prevención y control de la legionelosis: un reto para la salud pública española]]></article-title>
<article-title xml:lang="en"><![CDATA[Actions for legionellosis prevention and control: a challenge for public health in Spain]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gea-Izquierdo]]></surname>
<given-names><![CDATA[Enrique]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Mezones-Holguín]]></surname>
<given-names><![CDATA[Edward]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Haro-García]]></surname>
<given-names><![CDATA[Luis]]></given-names>
</name>
<xref ref-type="aff" rid="A04"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de MálagaUniversidad de Málaga Cátedra de Seguridad y Salud en el Trabajo ]]></institution>
<addr-line><![CDATA[Málaga ]]></addr-line>
<country>España</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Instituto Nacional de Salud Centro Nacional de Salud Pública Unidad de Análisis y Generación de Evidencias en Salud Pública]]></institution>
<addr-line><![CDATA[Lima ]]></addr-line>
<country>Perú</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad Peruana de Ciencias Aplicadas Escuela de Medicina ]]></institution>
<addr-line><![CDATA[Lima ]]></addr-line>
<country>Perú</country>
</aff>
<aff id="A04">
<institution><![CDATA[,Universidad Nacional Autónoma de México Facultad de Medicina Departamento de Salud Pública]]></institution>
<addr-line><![CDATA[México DF ]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2012</year>
</pub-date>
<volume>29</volume>
<numero>2</numero>
<fpage>272</fpage>
<lpage>276</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielosp.org/scielo.php?script=sci_arttext&amp;pid=S1726-46342012000200018&amp;lng=en&amp;nrm=iso&amp;tlng=en"></self-uri><self-uri xlink:href="http://www.scielosp.org/scielo.php?script=sci_abstract&amp;pid=S1726-46342012000200018&amp;lng=en&amp;nrm=iso&amp;tlng=en"></self-uri><self-uri xlink:href="http://www.scielosp.org/scielo.php?script=sci_pdf&amp;pid=S1726-46342012000200018&amp;lng=en&amp;nrm=iso&amp;tlng=en"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[La legionelosis es una enfermedad respiratoria con origen en sistemas que formen aerosol y que contenga el agente biológico Legionella sp. En las últimas décadas se ha desarrollado en España un marco normativo para su prevención y control. El presente artículo expone la epidemiología de la legionelosis y la importancia del control de la transmisión de la bacteria en la lucha contra la enfermedad. Para ello, se hace patente la revisión de las instalaciones críticas y la inclusión de otras nuevas en la legislación preventiva así como la estimación del riesgo, la mejora en los procesos de diagnóstico y el avance en nuevos protocolos de prevención.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Legionellosis is a respiratory disease originating in systems that produce aerosol and contain Legionella sp. In recent decades, Spain has developed a regulatory framework for prevention and control of legionellosis. This article describes the epidemiology of legionellosis and the importance of controlling the transmission of bacteria in the fight against the disease. In that regard, it becomes clear the role of reviewing critical facilities and the inclusion of new ones in the preventive legislation, the estimation of risk, and the improvement in the diagnostic processes and progress in new prevention protocols.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Legionelosis]]></kwd>
<kwd lng="es"><![CDATA[Legionella]]></kwd>
<kwd lng="es"><![CDATA[Legislación]]></kwd>
<kwd lng="es"><![CDATA[España]]></kwd>
<kwd lng="es"><![CDATA[Salud Pública]]></kwd>
<kwd lng="en"><![CDATA[Legionellosis]]></kwd>
<kwd lng="en"><![CDATA[Legionella]]></kwd>
<kwd lng="en"><![CDATA[Legislation]]></kwd>
<kwd lng="en"><![CDATA[Spain]]></kwd>
<kwd lng="en"><![CDATA[Public Health]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="justify"><b><font size="4" face="Verdana">Acciones de prevención y   control de la legionelosis: un reto para la salud pública española</font></b></p>      <p align="justify"><b><font face="Verdana">   Actions for legionellosis prevention and control: a challenge for public health   in Spain</font></b></p>      <p align="justify">&nbsp;</p>      <p align="justify"><b><font size="2" face="Verdana">   Enrique Gea-Izquierdo<sup>1,a</sup>, Edward Mezones-Holguín<sup>2,3,b</sup>, Luis Haro-García<sup>4,c</sup></font></b></p>      <p align="justify"><font size="2" face="Verdana">   1 Cátedra de Seguridad y Salud en el Trabajo, Universidad de Málaga. Málaga,   España.</font></p>      <p align="justify"><font size="2" face="Verdana">   2 Unidad de Análisis y Generación de Evidencias en Salud Pública, Centro   Nacional de Salud Pública, Instituto Nacional de Salud. Lima, Perú.</font></p>      <p align="justify"><font size="2" face="Verdana">   3 Escuela de Medicina, Universidad Peruana de Ciencias Aplicadas. Lima, Perú.</font></p>      <p align="justify"><font size="2" face="Verdana">   4 Departamento de Salud Pública, Facultad de Medicina, Universidad Nacional   Autónoma de México. México DF, México.</font></p>      <p align="justify"><font size="2" face="Verdana">   a Biólogo doctor en Ciencias Biológicas, máster en Medicina Preventiva y Salud   Pública, máster en Seguridad y Salud en el Trabajo; b médico maestro en Ciencias   en   Epidemiología Clínica; c médico especialista en Medicina Familiar y Salud en el   Trabajo, doctor en Ciencias</font></p>  <hr>      <p align="justify"><b><font size="2" face="Verdana">   RESUMEN</font></b></p>      ]]></body>
<body><![CDATA[<p align="justify"><font size="2" face="Verdana">   La legionelosis es una enfermedad respiratoria con origen en sistemas que formen   aerosol y que contenga el agente   biológico <i>Legionella sp.</i> En las últimas décadas se ha desarrollado en España un   marco normativo para su prevención   y control. El presente artículo expone la epidemiología de la legionelosis y la   importancia del control de la transmisión   de la bacteria en la lucha contra la enfermedad. Para ello, se hace patente la   revisión de las instalaciones críticas y la   inclusión de otras nuevas en la legislación preventiva así como la estimación   del riesgo, la mejora en los procesos de   diagnóstico y el avance en nuevos protocolos de prevención.</font></p>      <p align="justify"><font size="2" face="Verdana">   <b>Palabras clave:</b> Legionelosis; Legionella; Legislación; España; Salud Pública   (fuente: DeCS BIREME).</font></p>  <hr>      <p align="justify"><b><font size="2" face="Verdana">   ABSTRACT</font></b></p>      <p align="justify"><font size="2" face="Verdana">   Legionellosis is a respiratory disease originating in systems that produce   aerosol and contain <i>Legionella sp.</i> In recent   decades, Spain has developed a regulatory framework for prevention and control   of legionellosis. This article describes the   epidemiology of legionellosis and the importance of controlling the transmission   of bacteria in the fight against the disease. In   that regard, it becomes clear the role of reviewing critical facilities and the   inclusion of new ones in the preventive legislation,   the estimation of risk, and the improvement in the diagnostic processes and   progress in new prevention protocols.</font></p>      <p align="justify"><font size="2" face="Verdana">   <b>Key words:</b> Legionellosis; Legionella; Legislation; Spain; Public Health (source:   MeSH NLM).</font></p>  <hr>      <p align="justify"><b><font size="2" face="Verdana">   INTRODUCCIÓN   </font></b></p>      <p align="justify"><font size="2" face="Verdana">   La legionelosis es una enfermedad respiratoria   originada por la bacteria <i>Legionella sp.</i> de la familia   Legionellaceae. Este microorganismo tiene forma de   bacilo y dimensiones que oscilan entre 1,5 - 5 &#956;m de   largo por 0,5 - 0,7 &#956;m de ancho, con uno o más flagelos   polares o subpolares. Más de la mitad de las especies   de <i>Legionella sp.</i> han estado implicadas en infección   humana(1); y la <i>Legionella pneumophila</i> es causante   de aproximadamente 85% de las infecciones (2). La   familia comprende un género, <em>Legionella</em>, con 40   especies y más de 50 serogrupos; mientras que para   la especie <i>Legionella pneumophila</i> se han descrito   14 serogrupos (3). En la legionelosis existe un periodo   desde la infección hasta la aparición de los primeros   síntomas, que suele ser de 2-10 días (5 a 6 días es   más frecuente); aunque en algunos casos es variable,   pudiéndose describir periodos de hasta tres semanas   con una mortalidad de 10-15%. La <i>Legionella sp.</i> es   una bacteria ampliamente distribuida en los ambientes   acuáticos tanto naturales como antrópicos; tolerando   diversas condiciones físicoquímicas. Existe alguna   especie como <em>Legionella longbeacheae</em> que ha sido   aislada en tierra (4), aunque de manera ocasional,   siendo además una especie que se presenta fuera de   Europa.</font></p>      <p align="justify"><font size="2" face="Verdana">   Cuando la bacteria coloniza los medios no naturales   es capaz de desarrollarse siempre que se determinen   elementos amplificadores, mostrando riesgo elevado   si hay producción de aerosoles que provoquen su   dispersión (5). Sin embargo, el hecho de que se identifique   la bacteria en un sistema o dispositivo determinado   no es condicional que se desarrolle la enfermedad. El   microorganismo tiene que alcanzar determinado nivel   de concentración para la posible afectación de las   personas existiendo, además, variabilidad en el tiempo   de exposición.</font></p>      <p align="justify"><font size="2" face="Verdana">   La infección por <i>Legionella sp.</i> puede adquirirse   fundamentalmente en dos grandes ámbitos: el   comunitario y el hospitalario. En ambos casos la   enfermedad puede estar asociada con varios tipos de   instalaciones   y edificios; presentarse en forma de brotes   o casos agrupados asi como en casos esporádicos o   aislados. De hecho, la frecuencia de aparición de la   enfermedad es bastante relevante y constituye uno   de los tipos de neumonía infecciosa más frecuente en   el mundo tecnológicamente desarrollado. El control   y la prevención de desarrollo de la enfermedad se   fundamentan en la aplicación de medidas preventivas en   las fuentes de origen y en el mantenimiento preventivo   de los diferentes sistemas.</font></p>      <p align="justify"><font size="2" face="Verdana">   Si bien la presentación habitual de la enfermedad   es en forma de casos esporádicos, cada vez es más   frecuente la aparición en forma de casos agrupados   o brotes con un gran número de afectados. El origen   de un gran número de brotes comunitarios con un   elevado número de casos suelen estar asociados a   las torres de refrigeración; así también, la enfermedad   es habitual en pacientes hospitalizados. Sin embargo,   el reconocimiento de brotes de legionelosis es algo   inusual, cuando ocurren se muestran oportunidades   para comprender la epidemiología de la enfermedad e   impulsar mejoras en las estrategias de su prevención.   Debido al aumento en la movilidad internacional, se   hace difícil realizar investigaciones epidemiológicas para   la localización y eliminación de las fuentes de infección.   Es objeto de debate que las personas deberían estar   informadas sobre las distintas fuentes (6). Especialmente   notable es la notificación de casos conocidos como   “legionelosis del viajero” que, en países como España,   puede tener repercusión importante sobre el desarrollo   del turismo. La <i>Legionella sp.</i> causa 0,5-5% de los casos   de neumonía adquirida en la comunidad, donde 15%   de estos requieren hospitalización (7). Otros autores (8)   plantean que la incidencia de la infección por Legionella   es altamente variable, constituyendo entre el 1 y 27% de   las neumonías adquiridas en la comunidad.</font></p>      ]]></body>
<body><![CDATA[<p align="justify"><font size="2" face="Verdana">   <b>EPIDEMIOLOGÍA DE LA LEGIONELOSIS</b></font></p>      <p align="justify"><font size="2" face="Verdana">   La enfermedad muestra una distribución mundial con   representación en América del Norte, Suramérica,   Asia, África, Australia y Europa (9-14). A finales de los   años noventa, en Europa y según la Organización   Mundial de la Salud (15), se advirtió un aumento en el   número de países con aportación de datos referida a la   enfermedad, aun siendo muy variable su incidencia. Las   tasas correspondientes al año 1999 variaban desde 19,5   por millón de habitantes en Bélgica a uno por millón de   habitantes en Portugal; mientras que España presentaba   una tasa de 7,8. Sin embargo, estos datos podrían estar   infravalorados con respecto a la incidencia real, debido   a la existencia de <i>Legionella sp.</i> no consideradas por   estar desvinculadas del sector turístico. En Europa,   las cifras de incidencia notificada varían mucho de un   país a otro, dependiendo de las características de los   sistemas de vigilancia. El mayor número de casos es de   categoría desconocida (importante objeto de estudio),   aconteciendo el ámbito comunitario en segundo lugar.   Convendría resaltar la importancia de la legionelosis   relacionada con “los viajes al extranjero” y, al contrario   de como se podría pensar, el ámbito intrahospitalario   presenta un nivel inferior.</font></p>      <p align="justify"><font size="2" face="Verdana">   La legionelosis es una enfermedad de declaración   obligatoria en el estado español. El Real Decreto   2210/1995 (16), por el que se creó la Red Nacional de   Vigilancia Epidemiológica, establece la declaración   semanal para esta enfermedad, con datos epidemiológicos   básicos. Antes de 1996 no se consideraba enfermedad   de declaración obligatoria a nivel nacional. Desde 1997,   año de introducción de la legionelosis en la lista de   enfermedades de declaración obligatoria, la incidencia   de la enfermedad ha presentado una tendencia creciente   hasta el año 2002, con una tasa de crecimiento anual   en ese período del 52,5%. Este aumento en el número   de casos declarados está relacionado con la amplia   difusión del uso de la prueba de búsqueda de antígenos   en orina como técnica diagnóstica (en nuestro país se   aceptó como diagnóstico de caso confirmado en 1999)   y la progresiva sensibilización en toda la comunidad   científica por un mejor diagnóstico, control y prevención   de la enfermedad. El año 2000 la tasa de incidencia fue   de 1,9 por 100 000 habitantes que, frente al año 1999,   supuso un incremento del 74%. A partir del año 2002 hasta   el año 2009, se presenta una tendencia conservadora   de las tasas de incidencia de la legionelosis.</font></p>      <p align="justify"><b><font size="2" face="Verdana">   IMPORTANCIA DEL DESARROLLO   LEGISLATIVO EN LA PREVENCIÓN DE LA   LEGIONELOSIS</font></b></p>      <p align="justify"><font size="2" face="Verdana">   A nivel mundial, Gran Bretaña es uno de los primeros   países en implantar legislación y orientaciones técnicas   para minimizar el riesgo de <i>Legionella sp.</i> (17) En   España, debido a los brotes aparecidos en las distintas   comunidades autónomas y a la alarma social causada (no   siempre correspondida con la problemática sanitaria que   se le quiere dar), se impone una revolución en cuanto al   tratamiento legislativo de la prevención de la legionelosis.   La Constitución Española (18), en su artículo 43, reconoce   el derecho a la protección de la salud y determina que   compete a los poderes públicos organizar y tutelar la   salud pública a través de medidas preventivas y de las   prestaciones y servicios necesarios. El primer escalón de   desarrollo preventivo lo constituye la Ley de Prevención   de Riesgos Laborales (19) y sus normas complementarias,   como instrumento de protección de la seguridad y la   salud. Esta Ley es cita ineludible y pilar direccional del   desarrollo del marco normativo preventivo español,   siendo igualmente de obligada mención el Reglamento   de los Servicios de Prevención (20). En la evolución   histórica legislativa, la referencia inicial comunitaria es   la normativa publicada por la Comunidad de Madrid (21),   por la que se regulan los criterios higiénico-sanitarios que   deben reunir los aparatos de transferencia de masa de   agua en corriente de aire, y aparatos de humectación   para la prevención de la legionelosis.</font></p>      <p align="justify"><font size="2" face="Verdana">   Desde la óptica de la Salud Pública se consideran como   elementos críticos (22) las torres de refrigeración de agua,   los condensadores evaporativos y otros equipos de   intercambio aire-agua. Esto se debe a la capacidad de   producir aerosoles, que pueden transportar la bacteria   hacia el medioambiente cuando tales dispositivos se   encuentran en malas condiciones. Si se repasan los   brotes notificados en España durante los años 1989-   2000 (años en que se produce el inicio del desarrollo de   la normativa) se identifican 54 brotes, con 22 ocasiones   donde el sistema de agua caliente sanitaria estuvo   implicado. Curiosamente, las torres de refrigeración   que son las que más alarma social causan, únicamente   están relacionadas con 13 brotes de tipo comunitario   abierto, considerándose, a veces, poco relevantes los   ligados a otros sistemas. La normativa nacional de   prevención y control de la legionelosis (23) describe el   ámbito de aplicación, considerando las instalaciones,   y su probabilidad de proliferación y dispersión de   <i>Legionella sp.</i></font></p>      <p align="justify"><b><font size="2" face="Verdana">   DESARROLLO DE LA EVOLUCIÓN DE RIESGOS, ESTIMACIÓN DE RIESGO, CRITERIOS DE   DIAGNÓSTICOS Y NUEVOS PROTOCOLOS </font></b></p>      <p align="justify"><font size="2" face="Verdana">   La evaluación y el control de la <i>Legionella sp.</i> es   tema en constante renovación que en algunos países   adopta gran importancia, donde quizás exista cierta   relación entre el desarrollo de la enfermedad y el nivel   de industrialización. Existen otros en los que, o no se   conocen casos, o no están descritos, mientras que en   alguno es un hecho infrecuente (24). En concreto, la   vigilancia continuada; la definición de estrategias, y su   puesta en práctica; pueden mostrar resultados positivos   para la prevención de la legionelosis (25). Es cierto que   las condiciones de mantenimiento de los equipos así   como las condiciones atmosféricas reinantes pueden   tener un papel relevante; pero, en el medioambiente   urbano la enfermedad se asocia usualmente con diseños   deficientes en los edificios; construcción inapropiada, y   negligencia en el control de la calidad del agua de las   instalaciones.</font></p>      <p align="justify"><font size="2" face="Verdana">   En la estimación del riesgo, uno de los componentes   prioritarios de la investigación epidemiológica es la   identificación de la asociación causal entre determinado   factor de riesgo, y daño para la salud, encontrando   dificultades para la asignación del grado de exposición.   Adicionalmente, los efectos sobre la salud pueden ser   diferentes si afecta a edades tempranas o tardías, al   estado inmunológico de la persona, si se presentan   picos en la exposición y otros. Igualmente, el tipo de   sistema influye en el riesgo por <i>Legionella sp.</i> (<a href="#tab01">Tabla 1</a>)   variando de unos dispositivos a otros.</font></p>      <p align="justify"><font size="2" face="Verdana">   El criterio de diagnóstico de laboratorio(26) es aquel   compatible con la definición clínica de caso;y   cualquiera de los diagnósticos microbiológicos   considerados de confirmación como el aislamiento de   cualquier especie o serogrupo de Legionella a partir   de secreciones respiratorias, tejido pulmonar o sangre;   seroconversión (aumento del título de anticuerpos en   cuatro veces o más) con un segundo título mínimo   de 128 frente a <i>Legionella pneumophila</i> serogrupo 1   por inmunofluorescencia indirecta, en sueros tomados   en la fase aguda y convaleciente de la enfermedad;   y detección de antígeno <i>Legionella pneumophila</i>   serogrupo 1, en orina por RIA o ELISA. Las pruebas   anteriores se complementan unas a otras, por lo que   su realización aumenta la probabilidad de confirmar   el diagnóstico, teniendo en cuenta que ninguna de las   pruebas posee una sensibilidad del 100%.</font></p>      ]]></body>
<body><![CDATA[<p align="justify"><font size="2" face="Verdana">   La incapacidad para detectar el patógeno con cultivos   rutinarios y técnicas de tinción presenta un problema   en curso, ya que se debe considerar la implementación   de protocolos de cultivos especiales, y procedimientos   de antígenos urinarios. El reconocimiento temprano   de la bacteria conducirá a la iniciación de terapias   antimicrobianas efectivas (27). Igualmente, se plantea   la necesidad de desarrollo de métodos preventivos   que incidan en la producción basados en técnicas de   inspección rápida y que ayuden al mantenimiento de   los diferentes sistemas. Se considera que la forma   más adecuada para garantizar la uniformidad de   las actuaciones contempladas en los programas de   vigilancia y control es la elaboración de un documento   base para que los responsables de las instalaciones   desarrollen su propio plan de autocontrol.</font></p>      <p align="justify"><a name="tab01"></a></p>      <p align="center">    <a href="/img/revistas/rpmesp/v29n2/a18tab01a.jpg">  <img src="/img/revistas/rpmesp/v29n2/a18tab01.jpg" border="1"></a></p>      <p align="justify">&nbsp;</p>      <p align="justify"><b><font size="2" face="Verdana">                              CONCLUSIONES</font></b></p>      <p align="justify"><font size="2" face="Verdana">   El desarrollo normativo español para la prevención de   la legionelosis ha sufrido una enorme evolución en las   últimas décadas. Gracias a la instauración de medidas   de mejora, control y protección mediante tratamientos   de los distintos sistemas críticos, se ha avanzado en la   prevención de la dispersión del agente biológico y los   resultados de la enfermedad. La legislación aporta una   reducción en la exposición a la Legionella, minimizando   el posible riesgo mediante el control de las fuentes de   origen. Sin embargo, atendiendo a su epidemiología,   la enfermedad sigue presentándose como un reto   que superar. La consecuencia de la conjunción de las   medidas de salud pública y comunicación del riesgo,   conducirán al mejor conocimiento y control de los   mecanismos preventivos, remarcando la importancia   del marco legislativo como medio frente a la aparición   de la legionelosis. Al mismo tiempo, se requiere mayor   inspección sobre las labores realizadas por parte de   empresas especializadas autorizadas y las prestaciones   que de ellas se desprenden, así como la cualificación de   personal vinculado con la Administración. La existencia   de novedosas instalaciones o sistemas como posibles   fuentes de proliferación o dispersión de la bacteria,   precisa que sean incluidas en el ámbito de aplicación   del desarrollo de una nueva normativa española para la   prevención y control de la legionelosis.</font></p>      <p align="justify">&nbsp;</p>      <p align="justify"><b><font size="2" face="Verdana">   REFERENCIAS BIBLIOGRÁFICAS</font></b></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   1. Lo Presti F, Riffard S, Vandenesch F, Reyrolle M, Ronco   E, Ichai P, et al. The first clinical isolate of Legionella   parisiensis, from a liver transplant patient with pneumonia.   J Clin Microbiol. 1997;35(7):1706-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636246&pid=S1726-4634201200020001800001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font size="2" face="Verdana">   2. Marston BJ, Lipman HB, Breiman RF. Surveillance   for legionnaires’ disease. Risk factors for morbidity and   mortality. Arch Intern Med. 1994;154(21):2417-22.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636248&pid=S1726-4634201200020001800002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   3. Benson RF, Thacker WL, Wilkinson HW, Fallon RJ,   Brenner DJ. <i>Legionella pneumophila</i> serogroup 14 isolated   from patients with fatal pneumonia. J Clin Microbiol.   1988;26(2):382.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636250&pid=S1726-4634201200020001800003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   4. Travis TC, Brown EW, Peruski LF, Siludjai D, Jorakate   P, Salika P, et al. Survey of Legionella species found in   thai soil. Int J Microbiol. 2012;2012:218791. Epub 2012 Jan   12.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636252&pid=S1726-4634201200020001800004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   5. Gea-Izquierdo E. Cumplimiento de los protocolos de   prevención de la legionelosis en edificios públicos. Rev   Salud Publica (Bogota). 2009;11(1):100-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636254&pid=S1726-4634201200020001800005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <p align="justify"><font size="2" face="Verdana">   6. Kistler W, Fleisch F, Reinhart WH, Wieland T.   &#91;Legionellosis, a tourist problem?&#93;. &#91;Article in German&#93;.   Praxis (Bern 1994). 2002;91(31-32):1241-5.</font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   7. Greig JE, Carnie JA, Tallis GF, Ryan NJ, Tan AG,   Gordon IR, et al. An outbreak of legionnaires’ disease   at the Melbourne Aquarium, April 2000: investigation and   case-control studies. Med J Aust. 2004;180(11):566-72.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636257&pid=S1726-4634201200020001800007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   8. Cosentini R, Tarsia P, Blasi F, Roma E, Allegra L.   Community-acquired pneumonia: role of atypical organisms.   Monaldi Arch Chest Dis. 2001;56(6):527-34.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636259&pid=S1726-4634201200020001800008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   9. Silk BJ, Moore MR, Bergtholdt M, Gorwitz RJ, Kozak   NA, Tha MM, et al. Eight years of Legionnaires’ disease   transmission in travellers to a condominium complex in Las   Vegas, Nevada. Epidemiol Infect. 2012;4:1-10.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636261&pid=S1726-4634201200020001800009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   10. Cabello H, Cortés C, Ruiz M, Jover E, Rivera F, Segovia E,   et al. Neumonia adquirida en la comunidad. Comunicacion   de 8 casos de neumonia grave por <i>Legionella pneumophila</i>   serogrupo 1 en Chile. Rev Med Chil. 2002;130(3):309-13.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636263&pid=S1726-4634201200020001800010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   11. Lam MC, Ang LW, Tan AL, James L, Goh KT. Epidemiology   and control of legionellosis, Singapore. Emerg Infect Dis.   2011;17(7):1209-15.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636265&pid=S1726-4634201200020001800011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <p align="justify"><font size="2" face="Verdana">   12. Mehiri-Zghal E, Essalah L, Ghariani A, Mahjoubi W,   Reyrolle M, Meugnier H, et al. &#91;Molecular comparison of   <i>Legionella pneumophila</i> serogroup 1 isolated in Tunisia&#93;.   &#91;Article in French&#93;. Pathol Biol (Paris). 2008;56(5):279-82.</font></p>      ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font size="2" face="Verdana">   13. Brown J, Hort K, Bouwman R, Capon A, Bansal N,   Goldthorpe I, et al. Investigation and control of a cluster of   cases of Legionnaires disease in western Sydney. Commun   Dis Intell. 2001;25(2):63-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636268&pid=S1726-4634201200020001800013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   14. Blatny JM, Fossum H, Ho J, Tutkun M, Skogan G,   Andreassen O, et al. Dispersion of Legionella-containing   aerosols from a biological treatment plant, Norway. Front   Biosci (Elite Ed). 2011;1(3):1300-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636270&pid=S1726-4634201200020001800014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   15. World Health Organization (WHO). Legionnaires’ disease,   Europe, 1999. Wkly Epidemiol Rec. 2000;75(43):347-52.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636272&pid=S1726-4634201200020001800015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <p align="justify"><font size="2" face="Verdana">   16. Real Decreto 2210/1995, de 28 de diciembre, por el que se   crea la Red Nacional de Vigilancia Epidemiológica. B.O.E.   núm. 21 de 24 de enero de 1996.</font></p>      <p align="justify"><font size="2" face="Verdana">   17. Brundrett G. Controlling Legionnaire’s disease. Indoor and   Built Environment. 2003;12(1-2):19-23.</font></p>      <p align="justify"><font size="2" face="Verdana">   18. Constitución Española. B.O.E. núm. 311 de 29 de diciembre   de 1978.</font></p>      <p align="justify"><font size="2" face="Verdana">   19. Ley 31/1995, de 8 de noviembre, de Prevención de Riesgos   Laborales. B.O.E. núm. 269 de 10 de noviembre de 1995.</font></p>      ]]></body>
<body><![CDATA[<p align="justify"><font size="2" face="Verdana">   20. Real Decreto 39/1997, de 17 de enero, por el que se   aprueba el Reglamento de los Servicios de Prevención.   B.O.E. núm. 27 de 31 de enero de 1997.</font></p>      <p align="justify"><font size="2" face="Verdana">   21. Orden 1187/ 1998, de 11 de junio, de la Consejería de   Sanidad y Servicios Sociales de la Comunidad de Madrid,   por la que se regulan los criterios higiénico-sanitarios que   deben reunir los aparatos de transferencia de masa de   agua en corriente de aire y aparatos de humectación para   la prevención de la legionelosis. B.O.C.M. núm. 144 de 19   de junio de 1998.</font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   22. Gea-Izquierdo E. Prevención de la legionelosis en sistemas   de refrigeración de agua. Dyna. 2011;78(165):9-17.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636280&pid=S1726-4634201200020001800016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <p align="justify"><font size="2" face="Verdana">   23. Real Decreto 865/2003, de 4 de julio, por el que se   establecen los criterios higiénico- sanitarios para la   prevención y control de la legionelosis. B.O.E. núm. 171 de   18 de julio de 2003.</font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   24. Luna CM. Neumonía por Legionella, un hecho   infrecuente en Argentina ¿Diferente epidemiología o   marcador del subdesarrollo? &#91;carta&#93;. Medicina (B Aires).   1999;59(3):311-2.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636283&pid=S1726-4634201200020001800017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   25. Kelly AA, Danko LH, Kralovic SM, Simbartl LA, Roselle   GA. Legionella in the veterans healthcare system: report of   an eight-year survey. Epidemiol Infect. 2003;131(2):835-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636285&pid=S1726-4634201200020001800018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   26. Junta de Andalucía, Consejería de Salud. Protocolos   de Alerta Epidemiológica. Sevilla: Dirección General   de Salud Pública y Participación. Servicio de Vigilancia   Epidemiológica y Evaluación. SVEA-Sistema de Vigilancia   Epidemiológica de Andalucía; 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636287&pid=S1726-4634201200020001800019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <!-- ref --><p align="justify"><font size="2" face="Verdana">   27. Adams SL. Legionella: a new millennium bug. Clin Lab Sci.   1999;12(5):309-15.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=2636289&pid=S1726-4634201200020001800020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      <p align="justify">&nbsp;</p>      <p align="justify"><font size="2" face="Verdana">   <b>Correspondencia:</b> Enrique Gea-Izquierdo</font></p>      <p align="justify"><font size="2" face="Verdana">   Dirección: calle Doctor Ortiz Ramos s/n 29071. Málaga, España.</font></p>      <p align="justify"><font size="2" face="Verdana">   Teléfono: (34) 677454317</font></p>      <p align="justify"><font size="2" face="Verdana">   Correo electrónico: <a href="mailto:enriquegea&#64;telefonica.net">  enriquegea&#64;telefonica.net</a></font></p>      <p align="justify">&nbsp;</p>      <p align="justify"><font size="2" face="Verdana">   <b>Recibido:</b> 02-04-12 </font></p>      ]]></body>
<body><![CDATA[<p align="justify"><font size="2" face="Verdana"><b>Aprobado:</b> 13-06-12</font></p>      <p align="justify">&nbsp;</p>         ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lo Presti]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Riffard]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Vandenesch]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Reyrolle]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ronco]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Ichai]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The first clinical isolate of Legionella parisiensis, from a liver transplant patient with pneumonia]]></article-title>
<source><![CDATA[J Clin Microbiol]]></source>
<year>1997</year>
<volume>35</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1706-9</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Marston]]></surname>
<given-names><![CDATA[BJ]]></given-names>
</name>
<name>
<surname><![CDATA[Lipman]]></surname>
<given-names><![CDATA[HB]]></given-names>
</name>
<name>
<surname><![CDATA[Breiman]]></surname>
<given-names><![CDATA[RF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Surveillance for legionnaires’ disease. Risk factors for morbidity and mortality]]></article-title>
<source><![CDATA[Arch Intern Med]]></source>
<year>1994</year>
<volume>154</volume>
<numero>21</numero>
<issue>21</issue>
<page-range>2417-22</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Benson]]></surname>
<given-names><![CDATA[RF]]></given-names>
</name>
<name>
<surname><![CDATA[Thacker]]></surname>
<given-names><![CDATA[WL]]></given-names>
</name>
<name>
<surname><![CDATA[Wilkinson]]></surname>
<given-names><![CDATA[HW]]></given-names>
</name>
<name>
<surname><![CDATA[Fallon]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
<name>
<surname><![CDATA[Brenner]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Legionella pneumophila serogroup 14 isolated from patients with fatal pneumonia]]></article-title>
<source><![CDATA[J Clin Microbiol]]></source>
<year>1988</year>
<volume>26</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>382</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Travis]]></surname>
<given-names><![CDATA[TC]]></given-names>
</name>
<name>
<surname><![CDATA[Brown]]></surname>
<given-names><![CDATA[EW]]></given-names>
</name>
<name>
<surname><![CDATA[Peruski]]></surname>
<given-names><![CDATA[LF]]></given-names>
</name>
<name>
<surname><![CDATA[Siludjai]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Jorakate]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Salika]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Survey of Legionella species found in thai soil]]></article-title>
<source><![CDATA[Int J Microbiol]]></source>
<year>2012</year>
<volume>2012</volume>
<page-range>218791</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gea-Izquierdo]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cumplimiento de los protocolos de prevención de la legionelosis en edificios públicos]]></article-title>
<source><![CDATA[Rev Salud Publica (Bogota)]]></source>
<year>2009</year>
<volume>11</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>100-9</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kistler]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Fleisch]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Reinhart]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
<name>
<surname><![CDATA[Wieland]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Legionellosis, a tourist problem?]]></article-title>
<source><![CDATA[Praxis (Bern 1994)]]></source>
<year>2002</year>
<volume>91</volume>
<numero>31-32</numero>
<issue>31-32</issue>
<page-range>1241-5</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Greig]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Carnie]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Tallis]]></surname>
<given-names><![CDATA[GF]]></given-names>
</name>
<name>
<surname><![CDATA[Ryan]]></surname>
<given-names><![CDATA[NJ]]></given-names>
</name>
<name>
<surname><![CDATA[Tan]]></surname>
<given-names><![CDATA[AG]]></given-names>
</name>
<name>
<surname><![CDATA[Gordon]]></surname>
<given-names><![CDATA[IR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An outbreak of legionnaires’ disease at the Melbourne Aquarium, April 2000: investigation and case-control studies]]></article-title>
<source><![CDATA[Med J Aust]]></source>
<year>2004</year>
<volume>180</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>566-72</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cosentini]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Tarsia]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Blasi]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Roma]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Allegra]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Community-acquired pneumonia: role of atypical organisms]]></article-title>
<source><![CDATA[Monaldi Arch Chest Dis]]></source>
<year>2001</year>
<volume>56</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>527-34</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Silk]]></surname>
<given-names><![CDATA[BJ]]></given-names>
</name>
<name>
<surname><![CDATA[Moore]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
<name>
<surname><![CDATA[Bergtholdt]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gorwitz]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
<name>
<surname><![CDATA[Kozak]]></surname>
<given-names><![CDATA[NA]]></given-names>
</name>
<name>
<surname><![CDATA[Tha]]></surname>
<given-names><![CDATA[MM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Eight years of Legionnaires’ disease transmission in travellers to a condominium complex in Las Vegas, Nevada]]></article-title>
<source><![CDATA[Epidemiol Infect]]></source>
<year>2012</year>
<volume>4</volume>
<page-range>1-10</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cabello]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Cortés]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Ruiz]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Jover]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Rivera]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Segovia]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Neumonia adquirida en la comunidad. Comunicacion de 8 casos de neumonia grave por Legionella pneumophila serogrupo 1 en Chile]]></article-title>
<source><![CDATA[Rev Med Chil]]></source>
<year>2002</year>
<volume>130</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>309-13</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lam]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
<name>
<surname><![CDATA[Ang]]></surname>
<given-names><![CDATA[LW]]></given-names>
</name>
<name>
<surname><![CDATA[Tan]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
<name>
<surname><![CDATA[James]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Goh]]></surname>
<given-names><![CDATA[KT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Epidemiology and control of legionellosis, Singapore]]></article-title>
<source><![CDATA[Emerg Infect Dis]]></source>
<year>2011</year>
<volume>17</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1209-15</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mehiri-Zghal]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Essalah]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Ghariani]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Mahjoubi]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Reyrolle]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Meugnier]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Molecular comparison of Legionella pneumophila serogroup 1 isolated in Tunisia]]></article-title>
<source><![CDATA[Pathol Biol (Paris)]]></source>
<year>2008</year>
<volume>56</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>279-82</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brown]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Hort]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Bouwman]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Capon]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bansal]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Goldthorpe]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Investigation and control of a cluster of cases of Legionnaires disease in western Sydney]]></article-title>
<source><![CDATA[Commun Dis Intell]]></source>
<year>2001</year>
<volume>25</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>63-6</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Blatny]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Fossum]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Ho]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Tutkun]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Skogan]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Andreassen]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Dispersion of Legionella-containing aerosols from a biological treatment plant, Norway]]></article-title>
<source><![CDATA[Front Biosci (Elite Ed)]]></source>
<year>2011</year>
<volume>1</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>1300-9</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<collab>World Health Organization (WHO)</collab>
<article-title xml:lang="en"><![CDATA[Legionnaires’ disease, Europe, 1999]]></article-title>
<source><![CDATA[Wkly Epidemiol Rec]]></source>
<year>2000</year>
<volume>75</volume>
<numero>43</numero>
<issue>43</issue>
<page-range>347-52</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gea-Izquierdo]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Prevención de la legionelosis en sistemas de refrigeración de agua]]></article-title>
<source><![CDATA[Dyna]]></source>
<year>2011</year>
<volume>78</volume>
<numero>165</numero>
<issue>165</issue>
<page-range>9-17</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Luna]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Neumonía por Legionella, un hecho infrecuente en Argentina ¿Diferente epidemiología o marcador del subdesarrollo?]]></article-title>
<source><![CDATA[Medicina (B Aires)]]></source>
<year>1999</year>
<volume>59</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>311-2</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kelly]]></surname>
<given-names><![CDATA[AA]]></given-names>
</name>
<name>
<surname><![CDATA[Danko]]></surname>
<given-names><![CDATA[LH]]></given-names>
</name>
<name>
<surname><![CDATA[Kralovic]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Simbartl]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
<name>
<surname><![CDATA[Roselle]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Legionella in the veterans healthcare system: report of an eight-year survey]]></article-title>
<source><![CDATA[Epidemiol Infect]]></source>
<year>2003</year>
<volume>131</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>835-9</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>26</label><nlm-citation citation-type="book">
<collab>Junta de Andalucía^dConsejería de Salud</collab>
<source><![CDATA[Protocolos de Alerta Epidemiológica]]></source>
<year>2003</year>
<publisher-loc><![CDATA[Sevilla ]]></publisher-loc>
<publisher-name><![CDATA[Dirección General de Salud Pública y Participación. Servicio de Vigilancia Epidemiológica y Evaluación. SVEA-Sistema de Vigilancia Epidemiológica de Andalucía]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B20">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Adams]]></surname>
<given-names><![CDATA[SL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Legionella: a new millennium bug]]></article-title>
<source><![CDATA[Clin Lab Sci]]></source>
<year>1999</year>
<volume>12</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>309-15</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>